window.ga=window.ga||function(){(ga.q=ga.q||[]).push(arguments)};ga.l=+new Date; ga('create', 'UA-30861926-1', 'auto'); ga('require', 'GTM-M2BXSQ5'); ga('set', 'forceSSL', true); ga('set', 'anonymizeIp', true); ga('require', 'displayfeatures'); ga('require', 'cleanUrlTracker'); ga('require', 'outboundLinkTracker'); ga('require', 'ec'); ga('send', 'pageview'); ga('set', 'nonInteraction', true); setTimeout("ga('send', 'event', 'read', '20 seconds')", 20000); Lutz Pumpen | Membranpumpe für Chemikalien, Galvanik-Flüssigkeiten
REQUEST PRICE

Fields with * are required
LUTZ (U.K.) LTD. | Great Britain
Family business since 1954
julie.mcauley@lutz-jesco.com
+44 24 77 10 33 06
Lutz Membranpumpe DMP 3/8" aus PP

Double diaphragm pump DMP 3/8"

for chemicals, paints and varnishes

Material:

Werkstoffe: Membranen, Ventilkugeln, Dichtungen:

Preis anfragen

Fields with * are required
  • 5706-160
  • op verzoek
  • The PTFE models have a lower suction lift and are not suitable for liquids with a high solids content.
Description: Air operated Diaphragm pump is suitable for highly flammable...more
Product information "Double diaphragm pump DMP 3/8""

Material: Polypropylene (PP)
Diaphragm / valve balls / seals material: TPV (NBR-PP) / NBR / NBR
Note:


Materialen TPV (NBR-PP), TPV (NBR-PP), NBR

Description:

Air operated Diaphragm pump is suitable for highly flammable media. Perfect for the circulation and feeding of chemicals.

  • Typical applications: Chemical circulation and feed, liquids with solid particles such as paints and varnishes, electroplating fluids, etc.
  • Comes standard with the Max-Pass™ valve for high viscosities.
  • PTFE versions are equipped with a ball valve

Features & Benefits

  • Air-carrying components made of corrosion-resistant plastic
  • No lubricants and therefore no contamination of the pumped medium by lubricants
  • Absolutely dry running safe
  • Self-priming (even in dry condition)
  • No contamination of the environment or the product by oil mist
Technische Produktdaten
▼ WERKSTOFFE | MATERIAL | MATERIAAL ▼
Housing (material): PP (polypropylene), PVDF (polyvinylidene fluoride), PA (polyamide)
Seals (material): PTFE (polyvinylidene fluoride), NBR (nitrile butadiene rubber), FPM (fluorinated rubber), EPDM (ethylene-propylene-diene monomer)
Valve seat (material): PP (polypropylene), PVDF (polyvinylidene fluoride), Stainless steel
Valve ball (material): FPM (fluorinated rubber), PTFE (Polyvinylidenfluorid), NBR (Nitrile Butadiene Rubber), EPDM (ethylene-propylene-diene monomer)
Diaphragms (material): PTFE (polyvinylidene fluoride), TPV (NBR-PP) = NBR/PP-Compound, TPV (EPDM-PP) = EPDM/PP-Compound
Doppelmenbranpumpen (Werkstoff): non - metallic
▼ FÖRDERDATEN | OPERATING DATA | SPECIFICATIES ▼
Delivery rate (up to max. l/min)*: 34
Fluid temperature (max °C): 66, 93
Operating pressure (max. bar): 8,2
Solids (max. ø mm): 6,4
Suction lift dry (in m): 5,2
▼ PUMPWERK | PUMP TUBE | POMPWERK ▼
Lufteinlass (Zoll) innen: 1/4"
Druckstutzen (Zoll) innen: 3/8"
Luftauslass (Zoll) innen: 3/8"
Saugstutzen (Zoll) innen: 3/8"
▼ EIGENSCHAFTEN | PROPERTIES | EIGENSCHAPPEN ▼
Operating pressure (max. bar): 8,2
Version: Clamped version, Max-Pass™-Ventiltechnik
Type: DMP 3/8" PPB PP/TPV (NBR-PP), DMP 3/8" PPE PP/TPV (EPDM-PP), DMP 3/8" PPT PP/PTFE, DMP 3/8" PPV PP/FPM, DMP 3/8" KNE PVDF/TPV (EPDM-PP), DMP 3/8" KNT PVDF/PTFE, DMP 3/8" KNV PVDF/FPM, DMP 3/8" NTC PA/PTFE, DMP 3/8" NBC PA/TPV (NBR-PP), DMP 3/8" NVC PA/FPM

* Die max. Fördermenge ist ein ermittelter Wert mittels Prüfstand und gemessen mit Wasser bei einer Mediumstemperatur von ca. 20° C. Die Messung erfolgt am Druckstutzen der Pumpe, ohne Schlauch, Zapfpistole oder Durchflussmesser. Die im Einsatz erzielbare Fördermenge ist niedriger und hängt von der individuellen Anwendung, den Medieneigenschaften sowie der Konfiguration der Pumpe ab. Die max. Förderhöhe ist ebenso abhängig von Pumpenausführung, Motor und Medium. Die Viskositätswerte werden mit Öl ermittelt.

** Prüfaufbau: Medium Wasser / Diesel, Durchfluss in Vorzugsrichtung, Beruhigungsstrecke 0,2 m vor und nach dem Durchflusszähler