window.ga=window.ga||function(){(ga.q=ga.q||[]).push(arguments)};ga.l=+new Date; ga('create', 'UA-30861926-1', 'auto'); ga('require', 'GTM-M2BXSQ5'); ga('set', 'forceSSL', true); ga('set', 'anonymizeIp', true); ga('require', 'displayfeatures'); ga('require', 'cleanUrlTracker'); ga('require', 'outboundLinkTracker'); ga('require', 'ec'); ga('send', 'pageview'); ga('set', 'nonInteraction', true); setTimeout("ga('send', 'event', 'read', '20 seconds')", 20000); Pumpwerk PP
Lutz (U.K.) Ltd. | United Kingdom
Family business since 1954
julie.mcauley@lutz-jesco.com
+44 24 77 10 33 06
Pump tube PP

Pump tube PP

suitable for B2 Vario and B2 Battery

Dive depth:

  • 0102-570
  • upon request
  • not suitable for flammable media
Description: The Lutz Pump tube (stainless steel) is suitable for thin-bodied, oil-based...more
Product information "Pump tube PP"

Immersion depth: 500 mm
Seal type: Sealless (DL)


Description:

The Lutz Pump tube (stainless steel) is suitable for thin-bodied, oil-based lubricants, cold cleaners and softeners. With the appropriate Motor it is suitable for medium to large filling quantities. Depending on the requirements, the Pump tube can be operated with the electric motor B2 Vario or the battery version B2 Battery.

  • Media examples: Lubricant (oil-based), cold cleaner, plasticizer
  • For removing small quantities from hobbocks, canisters and barrels
  • Suitable for Motor B2 Vario and B2 Battery

Features & Advantages

  • No lubricants and therefore no contamination of the pumped medium
  • Optimized Drum emptying
  • Maintenance without special tools
  • Universally resistant shaft bearings made of ETFE/PTFE
  • Sealless design (DL) conditionally safe to run dry
Technische Produktdaten
▼ WERKSTOFFE ▼
Pump tube (material): PP (polypropylene)
Impeller (material): PP (polypropylene)
Mechanical seal (material): no seals in contact with the medium
Static seal (material): no seals in contact with the medium
Drive shaft (material): Hastelloy C (2.4610)
Bearing (material): ETFE / PTFE
▼ FÖRDERDATEN ▼
Delivery rate (up to max. l/min)*: 65
Delivery head (up to max. mWS)*: 12
Fluid temperature (max °C): 50
density (up to kg/dm³): 1.6
Viscosity (up to mPas): 400
▼ PUMPWERK / DURCHFLUSSMESSER / MEMBRANPUMPE ▼
Immersion length (mm): up to 500 mm, from 500 mm, from 1000 mm
Immersion tube diameter (up to mm): 32
Conveyor wheel shape / drive type: Radial-flow impeller
Seal type: Sealless (SL)
Thread (inch) outside: 1"
▼ EIGENSCHAFTEN ▼
Scope of delivery: Pumpwerk (PP)

* Die max. Fördermenge ist ein ermittelter Wert mittels Prüfstand und gemessen mit Wasser bei einer Mediumstemperatur von ca. 20° C. Die Messung erfolgt am Druckstutzen der Pumpe, ohne Schlauch, Zapfpistole oder Durchflussmesser. Die im Einsatz erzielbare Fördermenge ist niedriger und hängt von der individuellen Anwendung, den Medieneigenschaften sowie der Konfiguration der Pumpe ab. Die max. Förderhöhe ist ebenso abhängig von Pumpenausführung, Motor und Medium. Die Viskositätswerte werden mit Öl ermittelt.

** Prüfaufbau: Medium Wasser / Diesel, Durchfluss in Vorzugsrichtung, Beruhigungsstrecke 0,2 m vor und nach dem Durchflusszähler

Here yoll find all files for this article. more
Titel Description File name File size Date Action
Titel:
Pumpwerke B1/B2 Battery & B2 Vario
Description:
Betriebsanleitungen (deutsch)
File name:
0698-350_Pump_tube_B1_Battery_B2_Battery_de.pdf
File size:
0 kB
Datum:
15/09/2020 14:24
Action:
Titel:
Fasspumpe - B2 Vario
Description:
Betriebsanleitung (deutsch)
File name:
0698-130_Lutz_B2_Vario_de_en.pdf
File size:
0 kB
Datum:
15/09/2020 15:04
Action:
Titel:
Pump tubes - B1 & B2 Battery
Description:
Operating Manuals (english)
File name:
0698-350_Pump_tube_B1_Battery_B2_Battery_de.pdf
File size:
0 kB
Datum:
17/09/2020 11:18
Action:
Titel:
Drum pumps - B2 Vario
Description:
Operating Manuals (english)
File name:
0698-130_Lutz_B2_Vario_de_en.pdf
File size:
0 kB
Datum:
17/09/2020 11:29
Action:
Titel:
Pompwerks - B1 & B2 Battery
Description:
Operating Manuals (nederlands)
File name:
0698-352_Pump_tube_B1_Battery_B2_Battery_nl.pdf
File size:
0 kB
Datum:
18/09/2020 07:19
Action:
Titel:
Vatpomp - B2 Vario
Description:
Operating Manuals (nederlands)
File name:
0698-131_Lutz_B2_Vario_nl_fr_it.pdf
File size:
0 kB
Datum:
18/09/2020 07:26
Action:
Fragen und Antworten mehr
Hier finden Sie die häufigsten Fragen und die dazugehörigen Antworten zu diesem Artikel.
Eine Frage zum Artikel stellen

Die mit einem * markierten Felder sind Pflichtfelder. Die E-Mail wird nicht veröffentlicht.

Vielen Dank für das Stellen einer Frage. Wir werden versuchen, diese schnellstmöglichst zu beantworten.
Gleitringdichtung oder Dichtungslos?

Gleitringdichtung (GLRD)

Eine Gleitringdichtung kommt bevorzugt zum Einsatz, wenn Medien gefördert werden, welche auskristallisieren, kleben, verderben oder aushärten können. Mit Ihr wird vermieden, dass das Fördermedium in das Wellenführungsrohr eintreten kann. Dies erleichtert den Spülprozess der Pumpe und verhindert ein Festsetzen der Antriebswelle. Da sich im Betrieb zwischen den Gleitflächen der Gleitringdichtung ein Film aus Fördermedium einbringt, welcher der Schmierung dient, ist ein Trockenlauf dieser Pumpen zu vermeiden!

Dichtunglos (DL)

Dichtungslose Pumpwerke können Sie für alle anderen Anwendungsfälle einsetzen. Da hier keine mechanische Dichtung vorhanden ist, wird diese Variante auch bei kurzzeitigem Trockenlauf nicht beschädigt. Generell sollte Trockenlauf jedoch vermieden, und die Pumpe unter Aufsicht betrieben werden!

Laufrad oder Rotor?

In der Praxis zeigen sich 2 typische Einsatzarten:

Anforderung 1: 


Überwinden von langen Schlauchlängen, erhöhte Viskosität und Dichte des Fördermediums, und die damit verbundene Anforderung von größeren Förderhöhen erfordern den Einsatz des Laufrades.


Lösung: Laufrad (L) = Radialrad

Anforderung 2:


Freier Auslauf und keine wesentlichen Druckverluste, aber verbunden mit dem Wunsch nach großer Fördermenge.


Lösung: Rotor (R) = Axialrad

PP
Rotor
Pump tube PP Pump tube PP
suitable for B2 Vario and B2 Battery